How-to & Measurement
Scope 2 Emissions From Your Electricity Bill: A Worked Example for India
Turn twelve electricity bills into your Scope 2 emissions in four steps, using India's grid emission factor from the Central Electricity Authority.

TL;DR
Scope 2 is the greenhouse gas pollution behind the electricity you buy. To work it out: add up twelve months of units (kWh) from your bills, multiply by the grid emission factor, and divide by 1,000 for tonnes. For FY 2025–26 the Central Electricity Authority (CEA) gives an all-India weighted average of 0.675 kg of CO2 per kWh. A factory using 180,000 kWh a year has about 121 tonnes of Scope 2 CO2.
Who this is for
An SME whose customer has asked, "What are your Scope 2 emissions?" and who has electricity bills but no sustainability team. It builds on our guide to Scope 1, 2 and 3 emissions and the beginner's guide to calculating emissions.
Plain explanation
Burning coal, gas and diesel at a power station releases carbon dioxide. When you buy electricity from the grid, you are responsible for a share of that pollution, even though the smoke is somewhere else. That share is your Scope 2 emissions.
The calculation is one multiplication:
Emissions = electricity used (kWh) × emission factor (kg CO2 per kWh)
The emission factor says how much CO2 the grid released for each unit it generated. It falls as the grid gets more solar and wind.
India specifics
The CEA publishes the official factor for India in its CO2 Baseline Database for the Indian Power Sector. Version 22.0 (August 2026) gives, for FY 2025–26, an all-India weighted average of 0.675 tonnes of CO2 per megawatt-hour (MWh). That is the same as 0.675 kg per kWh. The same table also shows other values: an operating margin of 0.963, a build margin of 0.446 and a combined margin of 0.705. The weighted average was 0.774 in FY 2013–14, so the grid has become cleaner.
Which number should you use? The weighted average is the usual choice for company reporting, and it is the figure in our emission factor finder. If your customer names a different one, such as the combined margin, use theirs and say which you used. Always write the factor, its source and the year next to your answer. CEA publishes a new version about once a year, so check the latest before each reporting year.
SEBI's BRSR (Annexure 16, Principle 6) asks listed companies for their Scope 1 and Scope 2 emissions, and BRSR Core (Annexure 17A) has a greenhouse gas indicator too, which is why customers pass the question down to suppliers.
Worked example
Arjun's plastics moulding unit (fictional) pays its electricity bill every month. The units on the twelve bills for April 2025 to March 2026 add up to 180,000 kWh. The total cost is ₹14.4 lakh (₹1,440,000), about ₹8 a unit.
Step 1: collect the units. Use the kWh line on each bill, not the rupee amount. If a bill covers a different period, split it by days.
Step 2: add them. 180,000 kWh for the year.
Step 3: multiply. 180,000 kWh × 0.675 kg CO2/kWh = 121,500 kg CO2.
Step 4: convert. 121,500 kg ÷ 1,000 = 121.5 tonnes of CO2 for FY 2025–26. Round it to 122 tonnes in a form.
The answer to write: "Scope 2 (location-based): 121.5 tCO2 in FY 2025–26, from 180,000 kWh of grid electricity, using the CEA all-India weighted average factor of 0.675 kg CO2/kWh (CEA CO2 Baseline Database v22.0)."
If Arjun later installs rooftop solar and uses 30,000 kWh of it, he buys 150,000 kWh from the grid. His Scope 2 falls to 101.25 tonnes. Record the solar generation separately, from the inverter.
Checklist
- Collect all twelve bills for the financial year (April to March).
- Add the kWh, not the rupees.
- Multiply by the factor for the same year (0.675 kg CO2/kWh for FY 2025–26).
- Divide by 1,000 to get tonnes.
- Write down the factor, its source (CEA, version 22.0) and the year.
- Count diesel burned in your own generator as Scope 1, not Scope 2.
- Keep the bills as proof.
What to do next
Our emission factor finder holds the CEA grid factor and common fuel factors, with sources, so you do not have to hunt for them each year.
Current as of: 14 November 2026. The factor is the one published in CEA's CO2 Baseline Database, User Guide Version 22.0 (August 2026), Table S, for FY 2025–26. CEA publishes a new version about once a year: treat any factor older than 12 months as due for a recheck.
Sources:
- CEA CO2 Baseline Database for the Indian Power Sector, User Guide v22.0, Table S
- SEBI LODR Master Circular, 30 January 2026, Annexures 16 and 17A